32
1
When installing next to wood furnaces,
for safety reasons, a heat-resistant and
heat-insulating insulation plate is to be
installed on site to the same height as
the appliance and a minimum of 30 cm
deep.
3
To secure at the top, 2 holes with ø 2.8
mm as stamped can be drilled (Detail
C).
Electrical connection/cable
The electrical connection must be carried
out by a licensed installer.
A type H05VV-F cable or a higher value must
be used as the power supply lead.
The installation must be carried out using a
cable with a plug or, for a domestic installa-
tion, a separator with a contact opening of at
least 3mm is required which also separates
all poles of the appliance from the mains in
accordance with NIN 2000.
For a direct connection a cable length of at
least 120 cm is required.
1. Connect terminal as shown in the con-
nection diagram.
Connection diagram 400V
Phase definitions:
L1, L2, L3 (or R, S, T)
2. Secure the cord grip.
1
In case of repair the appliance must
be switched off from the mains.